Model(s): GH3/100, GH5/100, GH7/100, GH9/100, GH11/100, GH12/100, GH13/100
High pressure filters for compressed air applications up to 100 bar g with optimized flow rates and improved housing design for high energy efficiency, maximum reliability and safe operation.
Highly effective pleated media in four different grades provide an element surface that is four times the size, compared to the conventional wrapped design. The result is a reduced flow speed and efficient separation simultaneously with low pressure drop, thus providing cost reduction during operation with reliable separation performance.
By fastening the filter element via its base thread screwed on the tie-rod, this provides the greatest operating safety, even under the pressure pulsations in intermittent operation that are common for high pressure applications.
Features & Benefits of Parker Domnick Hunter GH 100 Series Compressed Air Filters:
• Optimised flow rates and compact filter housing.
• Improved housing design with double O-ring sealing.
• Threaded rod element fixing.
• Pleated elements.
• Complete filter including filter element and manual drain.
• As an option filters are also available without a drain.
• All filter sizes offer connectors for the installation of calibrated differential pressure gauges.
Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.
Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the
Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact us at 727-835-0649 or Toll Free at 800-761-4298.
*Scroll to the right to see entire chart on mobile.
PERFORMANCE CHARACTERISTICS
|
RESIDUAL OIL CONTENT |
0.01 mg/m³ @ 20 °C (XP), 0.5 mg/m³ @ 20 °C (ZP), n.a. (V), 0.003 mg/m³ @ 20 °C (A) |
FILTRATION EFFICIENCY |
99.99% to 99.99999%, depending on filter type |
ELEMENT CHANGE INTERVAL |
12 months for V, ZP, XP elements / 3 months or max. 1500 hours of operation for A elements |
MAXIMUM FLOW RATE (M³/H) |
188 @ 100 bar(g) to 2787 @ 100 bar(g) |
MAXIMUM FLOW RATE (CFM) |
111 @ 1450 psig to 1640 @ 1450 psig |
MAXIMUM OPERATING PRESSURE (BARG) |
100 |
MAXIMUM OPERATING PRESSURE (PSIG) |
1450 |
MAXIMUM OPERATING TEMPERATURE (F) |
176 or 104, depending on filter type |
MINIMUM OPERATING TEMPERATURE (C) |
1.5 |
MINIMUM OPERATING TEMPERATURE (F) |
34.7 |
WEIGHT (KG) |
2.8, 3.4, 18.2, 21.9, 28.3, 39.2 |
WEIGHT (LBS) |
6.17, 7.49, 40.12, 48.28, 62.39, 86.42 |
HEIGHT (MM) |
355, 232, 420, 297, 455, 332, 540, 417, 655, 532, 910, 787 |
HEIGHT (INCH) |
13.97, 9.13, 16.53, 11.69, 17.91, 13.07, 21.26, 16.42, 25.78, 20.94, 35.82, 30.98 |
WIDTH (MM) |
80, 116, 125 |
WIDTH (INCH) |
3.15, 4.56, 4.92 |
CONNECTION TYPE |
BSP-P (DIN ISO 228) |
MICRON RATING |
0.01, 1, 3, n.a., depending on filter type |
DRAIN PORT SIZE |
G1/4i |
PRE-TREATMENT REQUIREMENT |
depending on filter type |
CERTIFICATES |
PED Fluid Group II, TR |
APPLICATION TYPE |
Filtration of compressed air and gaseous Nitrogen |
BRAND |
Parker Domnick Hunter |
Dimensions in (mm) and weight lbs (kg)
*Scroll to the right to see entire chart on mobile.
Model |
A (mm) |
B (mm) |
C (mm) |
D (mm) |
Weight lbs (kg) |
GH3/100 |
80 |
355 |
25 |
100 |
2.8 |
GH5/100 |
80 |
355 |
25 |
115 |
2.8 |
GH7/100 |
80 |
420 |
25 |
185 |
3.4 |
GH9/100 |
116 |
455 |
25 |
170 |
18.2 |
GH11/100 |
116 |
540 |
25 |
270 |
21.9 |
GH12/100 |
125 |
655 |
33 |
365 |
28.3 |
GH13/100 |
125 |
910 |
33 |
560 |
39.2 |