TWP Series Externally Heated Desiccant Air Dryers

Replaced by NextGen TWP Series

A Parker Airtek TWP Series Externally Heated Desiccant Air Dryer will effectively remove contaminants such as dirt, water, and oil. The traditional adsorption principle used in this design is simple, robust and flexible. Continuous drying is accomplished by the operation of two desiccant towers.

Pressure dewpoint of -40°F (-40°C) and flowrate of 200 – 7500 scfm depending on model.

Call us TODAY at 727-835-0649 or
Toll Free at 800-761-4298

Get A Free Quote!

Model(s): TWP200, TWP250, TWP300, TWP400, TWP500, TWP600, TWP800, TWP1000, TWP1200, TWP1500, TWP2000, TWP2600, TWP3000, TWP4000, TWP5000, TWP6000, TWP7500

Compressed air is polluted with dirt particles, water, oil, oil vapor, and condensate. These contaminants result in high maintenance costs, premature wear, spoiled products and the failure of control systems. Compressed air is dried through one tower while the other desiccant tower is being regenerated. The regeneration heating cycle of desiccant is accomplished using a dry air purge flow heated by an external electric heater. The regeneration cooling cycle is performed using the same flow of dry compressed air taken from the desiccant air dryer outlet to ensure continuous dewpoint performance.

Features & Benefits of Parker Airtek TW Series Air Dryers:
• Flow rate starting at 200 scfm (340 m3/hr)
• Delivered air quality is in accordance with ISO 8573.1: 2001, the international standard for compressed air quality.
• Pressure dewpoints of -100°F (-70°C) & -40°F (-40°C) (ISO 8573.1: 2001 Classes 1 & 2) are available.
• Parker Airtek pre- and after compressed air filters - Standard
• PowerLoc Energy Management System* - Standard
• Low-wattage high incoloy sheathed heater for efficient regeneration
• High-efficiency, quiet running regenerative (up to 3000 scfm) or centrifugal blowers (4000 scfm and larger)
• Parker non-lubricated full-flow angle seat valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers up to 800 scfm.
• High performance, actuated butterfly switching valves, which carry a FIVE YEAR VALVE WARRANTY, are standard on dryers 1000 scfm and larger.
• Insulated tower, heater and purge lines increase dryer performance and efficiency by reducing radiant heat loss plus keeps the unit with the safety parameters set forth by OSHA.
• Easy to use Control Center affords superior dryer control along with digital telemetry for remote analysis of performance.
• Custom filter packaging*
• 7" LCD Touchscreen HMI, Allen-Bradley® PLC
• Flash drive port for transferring data log
• Serial communications port (optional)
• Emergency stop and standby mode
• Automatic data logging 24/7, 365 days of all operational information

*Optional equipment

Sizing and Model Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact us at 727-835-0649 or Toll Free at 800-761-4298.



PERFORMANCE CHARACTERISTICS
DRYER TECHNOLOGY Externally Heated Desiccant
BRAND Parker Airtek
PRE-INSTALLED OPTIONAL ACCESSORIES Pre and After Filter
CONNECTION TYPE 1”" NPT, 1 1/2"” NPT, 1 1/2" NPT, 2" NPT, 3" Flg, 4" Flg, 6" Flg, 8" Flg
MAXIMUM FLOW RATE (M³/H) 170, 229, 340, 425, 510, 680, 850, 1019, 1359, 1699, 2038, 2548, 3398, 4417, 5097, 6796, 8495, 10194, 13592
RATED INLET PRESSURE (PSI) 100
MAXIMUM OPERATING PRESSURE (PSI) 150, 135
MINIMUM OPERATING PRESSURE (PSI) 80
MAXIMUM OPERATING TEMPERATURE (F) 120
MINIMUM OPERATING TEMPERATURE (F) 50
MAXIMUM AMBIENT TEMPERATURE (F) 120
MINIMUM AMBIENT TEMPERATURE (F) 40
PURGE RATE 7, 9.45, 14, 17.5, 21, 28, 35, 42, 56, 70, 84, 105, 140, 182, 210, 280, 350, 420, 560
PREFILTER PART NUMBER JC0110-C, JC0150-C, JC0250-C, JC0350-C, JC0450-C, JC0625-C, JC0800-C, JC1000-C, JLA1603-C, JLA2100-C, JLA3200-C, JLA3206-C, Consult Rep.
AFTERFILTER PART NUMBER JC0150-FH, JC0250-FH, JC0350-FH, JC0450-FH, JC0625-FH, JC0800-FH, JC1000-FH, JLA1800-FH, JLA2600-FH, JLA3506-FH, Consult Rep.
PREFILTER REPLACEMENT ELEMENT JE-CC0110, JE-CC0150, JE-CC0350, JE-CC0450, JE-CC0625, JE-CC0800, (2) JAE3-C, (3) JAE3-C, (4) JAE3-C, Consult Rep.
AFTERFILTER REPLACEMENT ELEMENT JE-FC0150-HT, JE-FC0350-HT, JE-FC0450-HT, JE-FC0625-HT, JE-FC0800-HT, JAE4-FH, (2) JAE4-FH, (3) JAE3-FH, Consult Rep.
INSTALLED CONDENSATE DRAIN Timed Drain, Consult Rep.
TYPE Heated
*Scroll to the right to see entire chart.


For the complete list of all TWP Series models dimensions and weights see the TWP Series Brochure.


Also Available from mdi: Parker Transair Aluminum Pipe and Fittings for Compressed Air

Transair aluminum pipe is the ideal system for compressed air, vacuum, and inert gas applications. It offers significant savings on installation, maintenance and operating costs when compared to traditional compressed air piping systems. Its removable and interchangeable components allow users to easily modify production layouts or execute process changes within minutes. It's the only product with true push-to-connect fittings, eliminating the need to thread, solder or glue pipe. Its unique sealing technology guarantees Transair to be leak-free.