OFC Series Heatless Desiccant Air Dryers

Parker Airtek OFC Series is a heatless desiccant dryer designed specifically for oil, gas and related industries. The dryer provides instrument quality compressed air and is packaged for maximum reliability and long, trouble-free service life.

Parker Airtek's OFC Series of heatless desiccant dryers provide a continuous supply of dry, oil-free compressed air by automatically cycling the flow of air through two desiccant towers. Compressed air is dried through one tower while the other desiccant tower is being regenerated by a portion of the dried air. Cycling is controlled by a solid state controller.

Call us TODAY at 727-835-0649 or
Toll Free at 800-761-4298

Get A Free Quote!

Model(s): OFC15A1E, OFC23A1E, OFC36A1E, OFC50A1E, OFC80A1E, OFC105A1E, OFC140A1E, OFC220A1E, OFC280A1E, OFC360A1E, OFC500A1E

Considering the importance of filtration to dryer performance, Parker Airtek recommends that all OFC Series dryers are ordered as a complete, factory assembled air treatment system. Standard equipment includes: properly sized, factory installed coalescing pre-filter and particulate after-filter with automatic float drain system and visual element condition indicators. Oversized filters are selected for longer element life and low pressure drop.

Features & Benefits of Parker Airtek OFC Series Air Dryers:
• Air quality - clean dry, oil-free meets ISO 8573.1 Class 1.2.1
• cETLus Listed
• Reliable solid state controller eliminates the problems associated with antiquated cam timers.
• Superior valve performance.
• Four-way directional control valve has an average life expectancy of 150 million cycles even in the harshest environments (OFC15 thru OFC80).
• High cycle independent air operated angle seat valves specifically designed for compressed air service (OFC105 thru OFC500).
• Easily classified to governing code requirements, such as OSHA, CSA, CRN, NEC, etc.
• Flexible packaging available. See optional equipment.
• Low power requirement - less than 20 watts @120V/1Ph/60Hz electrical input.
• Few moving parts - low maintenance
• Compact design, lightweight with minimal installation space required.
• Fully automatic - operates continuously without attention.

Standard Equipment
• ETL Listed
• Electric 120V/1Ph/60Hz
• Solid State Controller
• NEMA 4X Panel Enclosure
• Separate Tower Fill and Drain Ports
• Schedule 80, A106B Piping, 3000# A105 Fittings
• ASME Code (OFC105 thru OFC500)
• High Life Cycle Switching Valves
• Safety Relief Valves
• Locally Mounted Tank Pressure Gauges
• Purge Adjustment Valve
• Purge Exhaust Muffler(s) (OSHA Approved)
• 304 Stainless Steel Control Tubing & Parker Fittings
• Mounted Pre-Filter and After-Filter
• CRN Registered Tanks and Filters

Optional Equipment
• NEMA 7 Construction
• Class 1, Div 1, Group C&D
• Class 1, Div 2, Group C&D
• Low Ambient Packages
• Non-Yellow Metal Construction
• Nickel Plated Safety Valve(s) and Exhaust Valve (OFC15 thru OFC80)
• Stainless Steel Inlet and Exhaust Valves with Nickel Plated Safety Valves (OFC105 thru OFC500)
• Powerloc Energy Management System

Sizing and Model Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact us at 727-835-0649 or Toll Free at 800-761-4298.



PERFORMANCE CHARACTERISTICS
APPLICATION Oil Field Construction
DRYER TECHNOLOGY Heatless Desiccant
BRAND Parker Airtek
PRE-INSTALLED OPTIONAL ACCESSORIES Pre and After Filter
CONNECTION TYPE 3/8" NPT, 1/2" NPT, 3/4" NPT, 1" NPT, 1 1/2" NPT
MAXIMUM FLOW RATE (M³/H) 25.49, 39.08, 61.16, 84.95, 135.92, 178.40, 237.86, 373.78, 475.72, 611.64, 849.51
RATED INLET PRESSURE (PSI) 100
MAXIMUM OPERATING PRESSURE (PSI) 150
MINIMUM OPERATING PRESSURE (PSI) 80
MAXIMUM OPERATING TEMPERATURE (F) 120
MINIMUM OPERATING TEMPERATURE (F) 50
MAXIMUM AMBIENT TEMPERATURE (F) 120
MINIMUM AMBIENT TEMPERATURE (F) 49
PURGE RATE 0
PREFILTER PART NUMBER C0020-C, JC0050-C, JC0085-C, JC0110-C, JC0150-C, JC0250-C, JC0350-C.
AFTERFILTER PART NUMBER JC0020-F, JC0050-F, JC0085-F, JC0110-F, JC0150-F, JC0250-F, JC0350-F
PREFILTER REPLACEMENT ELEMENT JE-CC0025, JE-CC0050, JE-CC0110, JE-CC0150, JE-CC0350
AFTERFILTER REPLACEMENT ELEMENT JE-FC0025, JE-FC0050, JE-FC0110, JE-FC0150, JE-FC0600
INSTALLED CONDENSATE DRAIN Times Solenoid Drain
*Scroll to the right to see entire chart.


For the complete list of all TWB Series models dimensions and weights see the OFC Series Brochure.


Also Available from mdi: Parker Transair Aluminum Pipe and Fittings for Compressed Air

Transair aluminum pipe is the ideal system for compressed air, vacuum, and inert gas applications. It offers significant savings on installation, maintenance and operating costs when compared to traditional compressed air piping systems. Its removable and interchangeable components allow users to easily modify production layouts or execute process changes within minutes. It's the only product with true push-to-connect fittings, eliminating the need to thread, solder or glue pipe. Its unique sealing technology guarantees Transair to be leak-free.
Continue...