Model(s): K-MT 35, K-MT 45, K-MT 60, K-MT 75, K-MT 95
Features & Benefits of Parker Zander ecodry KA-MT 35-95 Series Air Dryers:
• Pressure dew points down to -70°C
• Volume flows up to 940 m³/h @ 7 barg (100 psig)
• High performance pre- and post filters installed as standard
• Energy saving dew point dependent switching (DDS) as an option
• Highest quality air
• Energy efficient
• Very flexible due to a wide range of options and accessories
Energy Savings
Where an application calls for a unit able to cope with variations in operating pressure and load, the installation of a dew point sensor at the outlet of the dryer is available as an option. In such an operating mode, the changeover cycle between chambers only takes place when required, and is dependent on the required dew point being achieved. Only upon reaching this adjustable set dew point, does changeover to the regenerated chamber occur. This feature enables the drying phase to be lengthened and thus avoids the unnecessary use of purge air for regeneration and consequently provides energy savings.
Compressed air can be selectively dried to meet a dew point of -25°C down to -70°C.
Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the
Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact us at 727-835-0649 or Toll Free at 800-761-4298.
PERFORMANCE CHARACTERISTICS
|
MAXIMUM FLOW RATE (CFM) |
553 @ 101 psig / PDP -13°F and -40°F |
MAXIMUM OPERATING PRESSURE (BARG) |
16 |
MAXIMUM OPERATING PRESSURE (PSIG) |
232 |
MINIMUM OPERATING PRESSURE (BARG) |
5 |
MINIMUM OPERATING PRESSURE (PSIG) |
72.5 |
MAXIMUM AMBIENT TEMPERATURE (C) |
50 |
MINIMUM AMBIENT TEMPERATURE (C) |
1.5 |
IP RATING |
65 |
MAXIMUM OPERATING TEMPERATURE (C) |
50 |
MAXIMUM OPERATING TEMPERATURE (F) |
122 |
MINIMUM OPERATING TEMPERATURE (C) |
25 |
MINIMUM OPERATING TEMPERATURE (F) |
77 |
PORT SIZE |
1½" to 2½" |
CONNECTION TYPE |
BSP-P DIN ISO 228 |
ELECTRICAL REQUIREMENTS |
230V/50-60Hz |
CONTROLLER TYPE |
Multitronic |
DRYER TECHNOLOGY |
Heatless Adsorption |
PRESSURE DEWPOINT (C) |
-25°C to -70°C |
PRESSURE DEWPOINT (F) |
-13°F to -97°F |
BRAND |
Parker Zander |
CERTIFICATES |
PED 97/23/EG Module D+B Category II, others on request |
PREFILTER TYPE |
GL11XLD to GL14XLD |
AFTERFILTER TYPE |
GL9ZLDH to GL14ZLDH |
Dimensions (mm) and weight (kg)
Model |
A |
B |
C |
D |
E |
Weight |
K-MT 35 |
830 |
1810 |
585 |
1320 |
1320 |
210 |
K-MT 45 |
860 |
1820 |
605 |
1320 |
1320 |
249 |
K-MT 60 |
910 |
1870 |
635 |
1320 |
1320 |
277 |
K-MT 75 |
1020 |
2000 |
640 |
1515 |
1515 |
408 |
K-MT 95 |
1020 |
2020 |
670 |
1515 |
1515 |
510 |