TWB Series Blower Purge Desiccant Compressed Air Dryers
Parker TWB Series Blower Purge Desiccant Air Dryers achieve a pressure dewpoint of -40°F by using Blower Regeneration technology. In this design, the dryer uses a heat source and a blower to push large volumes of ambient air across the desiccant bed during regeneration, instead of using dry purge air from the system. As a result, the TWB design is the most energy efficient of the Twin Tower dryers in Parker’s offering.
Call us TODAY at 727-835-0649 or Toll Free at 800-761-4298
The TWB Series is the most advanced design in our desiccant dryer offering, it includes a heater and a blower for regeneration of the desiccant bed. This process is known as blower regeneration and is the most energy efficient option available. Instead of using dry compressed air for the purge cycle, a blower pushes hot ambient air
across the desiccant bed during regeneration. In order to cool down the desiccant bed, a small percentage of purge air is used at the end of the cycle before the towers switch.
Sizing and Model Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact us at 727-835-0649 or Toll Free at 800-761-4298.
How to Order
6. Low Ambient Temperature Package option covers dryers with filter package N, F or B only. The dryer must also have NEMA 4 protection class. Consult mdi if Low Ambient Temperature Package option is required for a dryer with filter package D or a protection class other than NEMA 4. 7. TWB201-1201 come with float drain on pre-filter as standard. TWB1501 and larger come with both a demand drain and timed solenoid drain on pre-filter as standard. Timed solenoid drain option code T is available for TWB201-1201 only. Use option code Y if both Instrument Package options G & T are required for TWB201-1201.
MODEL
Dewpoint
Min. Operating Pressure
Max. Operating Pressure4
Min. Operating Temp.
Max. Operating Temp.
Max Ambient Temp.
Electrical Supply5
TWB 201-1501
-40°F (-40°C)
80 psig (5.5 barg)
150 psig (10.3 barg)
50°F (10°C)
120°F (49°C)
120°F (49°C)
460 / 3 / 60
TWB 2001-7501
-40°F (-40°C)
80 psig (5.5 barg)
135 psig (9.3 barg)
50°F (10°C)
120°F (49°C)
120°F (49°C)
460 / 3 / 60
*Scroll to the right to see entire chart. 4. Pressure relief valve variance +/- 10%. TWB201-1501 pressure relief valve set at 165 psig. TWB2001-7501 pressure relief valve set at 150 psig. 5. Control power = 120V / 1Ph / 60Hz
MODEL
Flowrate @ 100 psig (scfm)
Blower (HP)
Heater (kW)
Dryer Air In/Out
Pre-Filter
After-Filter
TWB201
200
.75
6
1½" NPT
AAPX030GNFX
JC0350-FH
TWB301
300
1.5
6
1½" NPT
AAPX035GNFX
JC0350-FH
TWB401
400
1.5
9
2" NPT
AAPX040HNFX
JC0450-FH
TWB501
500
3
12
2" NPT
AAPX045HNFX
JC0625-FH
TWB601
600
3
12
2" NPT
AAPX045HNFX
JC0625-FH
TWB801
800
5
15
2" NPT
AAPX050INFX
JC0800-FH
TWB1001
1000
5
18
3" FLG
AAPX055JNFX
JC1008-FH
TWB1201
1200
4
25
3" FLG
AAPX055JNFX
JC1008-FH
TWB1501
1500
7.5
30
3" FLG
JZ-C01501NXX
JZ-F02500NXX
TWB2001
2000
7.5
38
4" FLG
JZ-C02001OXX
JZ-F03300OXX
TWB2601
2600
10
50
4" FLG
JZ-C03001OXX
JZ-F03320OXX
TWB3001
3000
10
60
6" FLG
JZ-C03001PXX
JZ-F03320PXX
TWB4001
4000
15
85
6" FLG
JZ-C04501PXX
JZ-F04000PXX
TWB5001
5000
20
100
6" FLG
JZ-C06001PXX
JZ-F07500PXX
TWB6001
6000
20
120
6" FLG
JZ-C06001PXX
JZ-F07500PXX
TWB7501
7500
25
150
8" FLG
JZ-C10500QXX
JZ-F07500QXX
*Scroll to the right to see entire chart. • Above information should be used as a guideline. Flows are at 100 psig inlet pressure, 100°F (38°C) inlet temperature and 100°F (38°C) ambient temperature. For specific applications, please consult mdi. • Weight includes desiccant (shipped loose TWB2001 and up). • Pressure relief valve variance +/- 10%.
Correction Factors
To obtain dryer capacity at new conditions, multiply nominal capacity x C1 x C2.
Inlet Temperature Correction Factor
Maximum Inlet Temperature (C1)
°F
80
85
90
95
100
105
110
115
120
°C
27
29
32
35
38
41
43
46
49
CF
1.17
1.17
1.17
1.15
1.00
0.87
0.76
0.66
0.58
*Scroll to the right to see entire chart.
Inlet Pressure Correction Factor for Standard TW Dryers
Minimum Inlet Pressure (C2)
psi g
80
85
90
95
100
105
110
115
120
125
130
bar g
5.51
5.86
6.21
6.55
6.89
7.24
7.58
7.93
8.27
8.62
8.96
CF
0.83
0.87
0.91
0.96
1.00
1.04
1.09
1.13
1.17
1.22
1.26
*Scroll to the right to see entire chart.
MODEL
Height1,2
Width1,2
Depth1,2
Weight3
in
mm
in
mm
in
mm
lbs
kg
TWB201
82
2082.8
57
1447.8
44
1117.6
1500
680
TWB301
84
2133.6
58
1473.2
44
1117.6
1900
862
TWB401
87
2209.8
65
1651.0
56
1422.4
2180
989
TWB501
85
2159.0
66
1676.4
49
1244.6
2840
1288
TWB601
89
2260.6
73
1854.2
52
1320.8
3420
1551
TWB801
96
2438.4
85
2159
60
1524.0
4490
2037
TWB1001
103
2616.2
78
1981.2
60
1524.0
5700
2585
TWB1201
116
2946.4
96
2438.4
69
1752.6
6300
2858
TWB1501
114
2895.6
114
2895.6
66
1676.4
7165
3250
TWB2001
113
2870.2
132
3352.8
72
1828.8
9850
4468
TWB2601
111
2819.4
156
3962.4
84
2133.6
12210
5538
TWB3001
111
2819.4
168
4267.2
84
2133.6
12650
5738
TWB4001
113
2870.2
180
4572.0
86
2184.4
18910
8577
TWB5001
112
2844.8
186
4724.4
102
2590.8
21590
9793
TWB6001
112
2844.8
186
4724.4
102
2590.8
24890
11290
TWB7501
137
3479.8
204
5181.6
106
2692.4
29490
13376
*Scroll to the right to see entire chart.
Notes:
1. Dimensions shown on Models TWB201—TWB801 are with Package B.
2. Dimensions shown on Models TWB1001—TW3001 are with Package F.
3. Weight includes desiccant (shipped loose Models TWB2001 and up).
Also Available from mdi: Parker Transair Aluminum Pipe and Fittings for Compressed Air
Transair aluminum pipe is the ideal system for compressed air, vacuum, and inert gas applications. It offers significant savings on installation, maintenance and operating costs when compared to traditional compressed air piping systems. Its removable and interchangeable components allow users to easily modify production layouts or execute process changes within minutes. It's the only product with true push-to-connect fittings, eliminating the need to thread, solder or glue pipe. Its unique sealing technology guarantees Transair to be leak-free. Continue...